There are two main types of Sound Insulation Test:


• Airborne Test (to BS EN ISO 140-4)
This type of test measures the resistance to the passage of airborne sound through separating walls or floors. This is carried out by the test engineer using a high power multidirectional loudspeaker which creates steady levels of noise which are measured at differing locations in both the source and receiving rooms. Such tests can take place vertically (through party floor) or horizontally (through party wall).

• Impact Test (to BS EN ISO 140-7)
A tapping machine, which generates impact sound, is used to measure the passage of sound through the floor insulation to the room directly below. With an Impact Test, it is important that it is conducted directly onto the bare floor and before the fitting of any carpets or other floor covering.

The Sound Insulation Test is carried out according to a strict code of conduct and whilst our Sound Test engineer will be happy to outline the process to you – he must be left alone whilst conducting the formal test itself.

 

 

Previous Article: When Should I Carry Out My Sound Insulation Test? Next Article: What is Involved and What Site Conditions Are Needed For the Sound Test to be Carried Out?

"ATSPACE has provided , and continues to provide, an outstanding service to a high standard."

Andy Gilliver, Persimmon Homes

Results

 

 

"A very prompt and efficient service that dealt with every aspect of my requirements in a professional way. If you're in need of any testing requirements to meet building regulations I'd recommend ATSPACE every time."

Mynott Associates Limited

Results

"We have Found ATSPACE Services reliable, professional and friendly at a competitive Price."

Lyndsay Thrower, Taylor Wimpey

Results

"Thank you for the Smoke shaft Air Pressure Test. The whole experience with ATSPACE has been a pleasure from the start and we are looking forward to working with you on the next job.”

Brian Keane, C.E.O, Cameron Ventures Group

Results

"Just a note to thank ATSPACE for the excellent service received on this most recent project. Your engineer put himself out to ensure that the Smoke shaft Air Pressure Test was carried out with the minimum of fuss (in a very tricky environment) and was a pleasure to have on site."

Olly Wigg Director, Bowson Leeway Homes

Results